Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

CUSTOMIZED VACUUM SYSTEMS

CUSTOMIZED VACUUM SYSTEMS

construction principle.This design step is important to calculate the size of the system and sets the basis of the further steps. Customer input – backing pump In this step it is useful to define the backing pump for the high vacuum system. The customer can specify the preferred pumping technology (dry or wet). Information about

DESIGNING STEAM JET VACUUM SYSTEMS

DESIGNING STEAM JET VACUUM SYSTEMS

Vacuum piping.Paragraph 6.3 of the Heat Exchange Institute's Standards for Steam Jet Vacuum Systems (4th ed.) details the pro-cedure for calculating pressure drop in vacuum systems. In general, the diameter of the piping between the process and the ejector system must be at least as large as the suction connection in the first-stage ejector.

Page 1 Vacuum Calculations USPAS June 2002

Page 1 Vacuum Calculations USPAS June 2002

Vacuum Calculations Page 5 System Design: Motivation This effort is undertaken to provide an understanding of the critical issues (e.g. conductance limiting components, surface outgassing and leak rates) in order to design the most cost-effective pumping system. Simple pumping calculations can lead to over-designing the

VacTran - Home

VacTran - Home

PEC has developed the most practical and reliable vacuum calculation software available for R&D and industrial applications. VacTran has been used by experienced industrial vacuum engineers, using common methods that are widely accepted in the vacuum industry. If you design, sell, test, or analyze vacuum systems, you need VacTran. Windows 10.

Back to Basics Pump Sizing

Back to Basics Pump Sizing

In a positive-displacement (PD) pump, a discrete amount of fluid is trapped, forced through the pump, and discharged. A gear pump is an example of a PD pump (Figure 2). This pumping principle produces a pulsating flow, rather than a smooth flow. Its output flow tends to vary little with respect to the pressure at the pump outlet, because the moving

Sizing Vacuum Pumps - VTech

Sizing Vacuum Pumps - VTech

the vacuum pump. Today's dual stage rotary vane pumps are designed more or less to meet the needs of the industry. Most manufacturers carry 5 to 7 sizes of vacuum pumps, ranging between 6.5 m3/h (3.8 CFM) to 145 m3/h (85 CFM). Ideally, the small to intermediate sized pumps are best suited (11.5 m3/h or 6.8 CFM to 18.0 m3/h or 10.6 CFM for .

Pump Capacity calculation

Pump Capacity calculation

Sep 09, 2018 · Relationship between Pump HP and discharge in LPS. The difference between water pressure and water flow | How Pipe Size Affects Water Flow - Duration: 8:39. Wendell Lee Well Services 17,996 views

Pump calculations - The Engineering Mindset

Pump calculations - The Engineering Mindset

Sep 11, 2017 · To calculate the new pump head pressure from an increase or decrease in pump speed rpm, the following formula and calculation can be used. Calculate head pressure for an increase or decrease in pump speed rpm. To calculate the new pump impeller diameter to suit a change in pump flow rate, the following formula and calculation and be used. .

Calculating Evacuation Time - Vacuum Furnace Engineering .

Calculating Evacuation Time - Vacuum Furnace Engineering .

The pumping speed against pressure graph for a vacuum booster pump is not a smooth curve. The graph varies from manufacturer to manufacturer even though the pump design is based on the original Roots design. The pump speed curve is similar to a bell-shaped curve and rises to a peak from startup and then drops off as the pressure drops. (Fig. 3)

Centrifugal vacuum pump - All industrial manufacturers .

Centrifugal vacuum pump - All industrial manufacturers .

Find your centrifugal vacuum pump easily amongst the 44 products from the leading brands (Edwards, Pfeiffer Vacuum, Oerlikon, .) on DirectIndustry, the industry specialist for your professional purchases.

How to choose the right Vacuum Pump - HD Industrial Design

How to choose the right Vacuum Pump - HD Industrial Design

Recommended Oil Filled Rotary Vane Vacuum Pumps: 3-CFM Single Stage Vacuum Pump - 2424 Models. 5-CFM Two-Stage Vacuum Pump - 2424 & 3624 Models. 8-CFM Two-Stage Vacuum Pump - 2424 & 3624 Models. Other considerations. If you purchase one of our pre converted vacuum pumps, you don't need to do anything else.

xample of Vacuum calculation - AVS

xample of Vacuum calculation - AVS

Forall subsequent calculations it isimportant to know the massof the workpiece to be handled. Thiscan be calculated with the following formula: Mass m [kg ]:m = L x B x H x ρ L = lenght [m] B= width [m] H = hight [m] ρ= density[kg/m3] Example: m = 2,5 x 1,25 x 0,0025 x 7850 m = 61,33 kg xample of Vacuum calculation System design - the procedure

Vacuum calculation tool

Vacuum calculation tool

For those who would like a quick estimate, we have devised a free vacuum calculation tool that shows the evacuation performance for a given speed curve. With the online tool, you will learn more about: The impact of the vacuum chamber volume on evacuation time; The speed curve for different vacuum pump .

Fundamentals of Vacuum | Hydraulics & Pneumatics

Fundamentals of Vacuum | Hydraulics & Pneumatics

To calculate a system's vacuum needs, consider all work devices to be driven. The working vacuum of the devices can be determined by calculations based on handbook formulas, theoretical data, catalog information, performance curves, or tests made with prototype systems. . Depending on pump design, the vacuum limit ranges from 28 to 29.5 in .

Vacuum Ejectors - Schmalz

Vacuum Ejectors - Schmalz

Vacuum generators provide the required vacuum. The vacuum is generated either pneumatically (ejectors) or electrically (pumps, blowers). Pneumatic vacuum generators implement short cycle times and can be integrated directly into the system due to their compact and lightweight design. Ejectors offer intelligent functions for energy and process .

VacTran - Home

VacTran - Home

PEC has developed the most practical and reliable vacuum calculation software available for R&D and industrial applications. VacTran has been used by experienced industrial vacuum engineers, using common methods that are widely accepted in the vacuum industry. If you design, sell, test, or analyze vacuum systems, you need VacTran. Windows 10.

Vacuum calculation tool

Vacuum calculation tool

For those who would like a quick estimate, we have devised a free vacuum calculation tool that shows the evacuation performance for a given speed curve. With the online tool, you will learn more about: The impact of the vacuum chamber volume on evacuation time; The speed curve for different vacuum pump .

Pipe Vacuum Pressure Load Equations Formulas Design Calculator

Pipe Vacuum Pressure Load Equations Formulas Design Calculator

Pipe Vacuum Pressure Load Equations Formulas Design Calculator Fluid Mechanics Hydraulics. Solving for vacuum load per linear length of pipe. Inputs: internal vacuum pressure (P V)

Medical Vacuum Pump Sizing Calculator - Pattons Medical

Medical Vacuum Pump Sizing Calculator - Pattons Medical

Enter the hospital details to calculate your vacuum pump requirement. Note ! All the inputs should have value, if not applicable please enter 0.

Venturi Vacuum Generators - EDGE

Venturi Vacuum Generators - EDGE

When To Use A Vacuum Pump Versus A Venturi The application determines which one of the two methods is better suited. Though most applications can use vacuum from either one of the sources, one will clearly outweigh the other depending upon the design and application requirements from the point of view of cost, space, temperature etc.

Pump Power Calculation Formula | Specific speed of a .

Pump Power Calculation Formula | Specific speed of a .

Specific Speed of Pump. The specific speed "Nq" is a parameter derived from a dimensional analysis which allows a comparison of impellers of various pump sizes even when their operating similar Q -H range.. The specific speed can be used to classify the optimum impeller design. Specific Speed of pump (Nq) is defined as the speed in RPM at which a geometrically similar impeller would run if .

Pump calculations - The Engineering Mindset

Pump calculations - The Engineering Mindset

Sep 11, 2017 · To calculate the new pump head pressure from an increase or decrease in pump speed rpm, the following formula and calculation can be used. Calculate head pressure for an increase or decrease in pump speed rpm. To calculate the new pump impeller diameter to suit a change in pump flow rate, the following formula and calculation and be used. .

Vacuum pump - Wikipedia

Vacuum pump - Wikipedia

History Early pumps. The predecessor to the vacuum pump was the suction pump. Dual-action suction pumps were found in the city of Pompeii. Arabic engineer Al-Jazari later described dual-action suction pumps as part of water-raising machines in the 13th century. He also said that a suction pump was used in siphons to discharge Greek fire. The suction pump later appeared in medieval Europe from .

How to Calculate Water Pump Horsepower: 14 Steps (with .

How to Calculate Water Pump Horsepower: 14 Steps (with .

Mar 29, 2019 · To calculate the horsepower of a water pump, check the water level in the base reservoir tank to ensure it's full, and empty the second tank, or the destination reservoir. Measure the vertical distance between the water level in the base reservoir tank and the water input at the destination tank and write down the measurement in feet.

Conductance & Throughput in Vacuum Pipelines

Conductance & Throughput in Vacuum Pipelines

Oct 10, 2013 · Last month we discussed Gas Molecules and Gas Flow and at the end of the article mentioned the term Conductance. This time we will talk a bit more about conductance in vacuum system piping and why it has to be taken into consideration in the design of a typical vacuum furnace or similar vacuum system. Firstly though, we will discuss Throughput.

Vacuum pump - Wikipedia

Vacuum pump - Wikipedia

History Early pumps. The predecessor to the vacuum pump was the suction pump. Dual-action suction pumps were found in the city of Pompeii. Arabic engineer Al-Jazari later described dual-action suction pumps as part of water-raising machines in the 13th century. He also said that a suction pump was used in siphons to discharge Greek fire. The suction pump later appeared in medieval Europe from .

Proper Piping for Vacuum Systems

Proper Piping for Vacuum Systems

carefully look at the pump NPSH, but generally a suction head of 4-5 ft is adequate. The only other design criterion is sizing the control valve to satisfy downstream conditions. HYBRID SYSTEMS Some designs feature ejectors with a shell-and-tube intercondenser plus a liquid ring vacuum pump (LRVP). In such configurations, the LRVP must

How to Calculate NPSHa for Systems Under Vacuum | Pumps .

How to Calculate NPSHa for Systems Under Vacuum | Pumps .

Nov 19, 2018 · The application example for this article is a steam condenser. Condensers operate in a vacuum by design because this approach maximizes efficiency for the steam system. If you are applying pumps in commercial or industrial applications, you will eventually encounter a situation where the liquid on the suction side of the pump is under vacuum.

Pump Capacity calculation

Pump Capacity calculation

Sep 09, 2018 · Relationship between Pump HP and discharge in LPS. The difference between water pressure and water flow | How Pipe Size Affects Water Flow - .

Vacuum Pump Sizing - Evacuating A Chamber - VACUUBRAND

Vacuum Pump Sizing - Evacuating A Chamber - VACUUBRAND

Another common application for vacuum pumps is to simply pump down a chamber in order to establish a vacuum level, where there are no vapors being generated. This process sounds like a relatively simple calculation would be sufficient – where the flow rate would simply equal the volume that needs to be pumped out divided by time.